Siemens SIMATIC NTLM weakness lets attackers impersonate users, no fix yet

CISA has republished a Siemens advisory on CVE-2026-58114. The flaw affects every version of fourteen SIMATIC products, including WinCC, PCS 7 and Process Historian, and lets an on-path attacker relay NTLM authentication. Operators of industrial systems running this software are concerned, particularly because Siemens has not yet released fixes.

What to do now Illustration photo (data center)
CVSS severity7.7High
EPSS probability0 %
ExploitationNot observed
PatchWorkaround
Product
Siemens SIMATIC (BATCH, PCS 7, Information Server, Process Historian, WinCC, WinCC Runtime Professional)
Affected versions
All versions: BATCH V9.1, PCS 7 V9.1, Information Server and Process Historian 2020/2022, WinCC V7.5 to V8.1, WinCC Runtime Professional V17 to V21
Fixed in
No fix available yet; Siemens says fixes are in preparation
CVE
CVE-2026-58114

On 17 November 2026, CISA published an advisory covering several Siemens SIMATIC process control and supervision applications. They contain an authentication bypass vulnerability tracked as CVE-2026-58114.

The issue lies in remote user authentication, which relies on the deprecated NTLM protocol and is not adequately protected. An unauthenticated attacker who manages to sit between a client and a server on the network can relay that authentication and pose as a legitimate user. According to the advisory, this could let the attacker take over the victim's session and run arbitrary code with that user's privileges.

How damaging an attack would be depends on which services the targeted machine can reach. The advisory gives the SQL server used by WinCC as an example.

All versions of the following products are listed as affected: SIMATIC BATCH V9.1, SIMATIC PCS 7 V9.1, SIMATIC Information Server 2020 and 2022, SIMATIC Process Historian 2020 and 2022, SIMATIC WinCC V7.5, V8.0 and V8.1, and SIMATIC WinCC Runtime Professional V17, V18, V19, V20 and V21. The products are deployed worldwide, mainly in the critical manufacturing sector.

Siemens says it is preparing fixes, but the advisory names no patched release. In the meantime, the vendor recommends mitigations that customers apply through manual configuration. The excerpt we received is cut off before those settings are described, so administrators should consult the full Siemens or CISA advisory for the exact steps.

Action plan

What to do now

  1. Inventory every SIMATIC BATCH, PCS 7, Information Server, Process Historian, WinCC and WinCC Runtime Professional installation in your environment.
  2. Apply the manual configuration mitigations described in the full Siemens advisory (ICSA-26-321-08) to the affected products.
  3. As general good practice, restrict network access to these systems and their supporting services, such as the WinCC SQL server, to only the hosts that need it.
  4. Review authentication logs for unusual NTLM logons and track Siemens' announced fixes so you can install them once released.