English edition · cyberattaques.org in FrenchFrançais
VulnerabilityPatch available

Siemens RUGGEDCOM APE1808 affected by Brotli decoder flaw in embedded PAN-OS

CISA has republished a Siemens advisory stating that every version of the RUGGEDCOM APE1808 is affected by CVE-2026-111497, a buffer overflow in the Brotli decoder used by Palo Alto Networks PAN-OS. Operators of industrial networks running this module, particularly in critical manufacturing, are concerned.

What to do now Illustration photo (security lock digital)
CVSS severity9.2Critical
EPSS probability82 %
ExploitationNot observed
PatchAvailable
Product
Siemens RUGGEDCOM APE1808 (PAN-OS)
Affected versions
RUGGEDCOM APE1808: all versions; Google Brotli 1.0.3 through 1.2.0
Fixed in
Corresponding fixed PAN-OS release; Brotli 1.0.10, 1.1.1 or 1.2.1
CVE
CVE-2026-111497

On 12 November 2026 CISA released an advisory covering the Siemens RUGGEDCOM APE1808, an industrial platform that runs Palo Alto Networks PAN-OS. It follows a Palo Alto Networks disclosure about a PAN-OS vulnerability, which the source links to an issue referred to as Node2Shell, and lists the Siemens products affected.

The flaw, tracked as CVE-2026-111497, sits in the decoder of the Google Brotli compression library, in c/dec/decode.c, and is classed as an out-of-bounds write (CWE-787). According to the description, Brotli versions 1.0.3 through 1.2.0 are vulnerable on all platforms.

A remote attacker with no credentials can trigger it by supplying a crafted Brotli-compressed stream. Successful exploitation could corrupt the decoder's state memory, leak sensitive memory contents, crash the service, or potentially lead to arbitrary code execution.

Siemens lists all versions of the RUGGEDCOM APE1808 with PAN-OS as known affected. The vendor fix is to upgrade to the matching patched PAN-OS release, and Siemens asks customers to contact its support team for patch and update details. The advisory also points to the workarounds in Palo Alto Networks' own security notices. For the Brotli library itself, the fixed releases are 1.0.10, 1.1.1 and 1.2.1.

The device is deployed worldwide, mainly in the critical manufacturing sector. Siemens ProductCERT reported the issue to CISA. The source does not say whether the vulnerability is being exploited in the wild.

Action plan

What to do now

  1. Inventory every RUGGEDCOM APE1808 in your environment and note the PAN-OS version it runs.
  2. Upgrade PAN-OS to the corresponding fixed release from Palo Alto Networks, contacting Siemens support for update details.
  3. Until the upgrade is done, apply the workarounds described in Palo Alto Networks' security notifications.
  4. Update any other Brotli library or binary in the 1.0.3 to 1.2.0 range to 1.0.10, 1.1.1 or 1.2.1.
  5. As general good practice recommended by Siemens, restrict network access to these devices and keep them in a protected network segment.