Schneider Electric flaw enables remote code execution on EcoStruxure IT Gateway and AP9475

CERT-FR has flagged CVE-2026-114938 in several Schneider Electric products, a flaw that can be exploited remotely to run arbitrary code or cause a denial of service. EcoStruxure Energy Operation, EcoStruxure IT Gateway and the Enterprise server AP9475 are affected.

What to do now Illustration photo (data center power equipment)
CVSS severity8.1High
EPSS probability59 %
ExploitationNot observed
PatchAvailable
Product
Schneider Electric EcoStruxure IT Gateway, EcoStruxure Energy Operation, Enterprise server AP9475
Affected versions
EcoStruxure Energy Operation all versions; IT Gateway 1.21.0.6 to 1.24.0.12 and 2.0.0.20 to 2.3.0.10; Enterprise server AP9475 9.0 and later
CVE
CVE-2026-114938

France's CERT-FR issued advisory CERTFR-2026-AVI-1618 on 25 November 2026, based on Schneider Electric security notice SEVD-2026-328-01 published the day before. It covers a single vulnerability, tracked as CVE-2026-114938.

According to the advisory, a remote attacker can use the flaw to execute arbitrary code or knock the service offline. CERT-FR does not describe the underlying weakness, the conditions required for exploitation or whether authentication is needed, and it does not report any exploitation in the wild.

Several products are in scope. EcoStruxure Energy Operation is affected in all versions. EcoStruxure IT Gateway is vulnerable in two branches: 1.21.0.6 through 1.24.0.12, and 2.0.0.20 through 2.3.0.10. The Enterprise server AP9475 is affected from version 9.0 onward.

CERT-FR points administrators to the vendor notice for the fixes. The advisory itself does not list the corrected version numbers, so the Schneider Electric document SEVD-2026-328-01 is the reference for which update to deploy on each product.

These tools are used to monitor energy infrastructure and data centre equipment, so a compromise could reach beyond ordinary IT systems. Identifying where they run should be a priority.

Action plan

What to do now

  1. Inventory every EcoStruxure Energy Operation, EcoStruxure IT Gateway and Enterprise server AP9475 instance and check its version against the affected ranges.
  2. Read Schneider Electric notice SEVD-2026-328-01 to find and install the fix for each product.
  3. Until patched, follow good practice by restricting network access to these systems to administration hosts and keeping them off the internet.
  4. Review logs on these systems for unexpected restarts or unusual connections.