Node.js Brotli flaw "Node2Shell" affects a wide range of Siemens industrial software
Siemens has issued an advisory, republished by CISA, on how CVE-2026-111497, an out-of-bounds write in the Brotli decoder bundled with Node.js, affects its industrial automation software. Operators of WinCC, TIA Administrator, UMC, BRAUMAT, SISTAR and COMOS Walkinside are concerned, particularly in manufacturing, food and agriculture, and energy.
What to do now
- Product
- Siemens Industrial Automation Software (SIMATIC WinCC, TIA Administrator, UMC, COMOS Walkinside and others)
- Affected versions
- All versions of WinCC V7/V8, Unified, Runtime Pro, OA V3.21, TIA Administrator, UMC, COMOS Walkinside; BRAUMAT/SISTAR 8.2.0.1 to <8.2.0.5; WinCC OA V3.20 <3.20.17.1
- Fixed in
- BRAUMAT and SISTAR 8.2.0.5; WinCC OA V3.20 3.20.17.1 (based on the affected ranges)
- CVE
- CVE-2026-111497
On October 21, 2026, the Node.js project shipped security updates for a critical vulnerability in its bundled Brotli decoder. Nicknamed "Node2Shell" and tracked as CVE-2026-111497, the bug is an out-of-bounds write that a remote attacker could use to corrupt memory and potentially run arbitrary code.
Several Siemens industrial products are built on Node.js and inherit the flaw. According to the advisory CISA published on November 17, 2026, every version of the following is affected: COMOS Walkinside, Project Server Web Administration Tool, SIMATIC Profiling Tool, SIMATIC WinCC Companion, SIMATIC WinCC OA V3.21, SIMATIC WinCC Runtime Professional, SIMATIC WinCC Unified for Industrial Edge, SIMATIC WinCC Unified PC Runtime, SIMATIC WinCC Unified SIQENCE, SIMATIC WinCC V7/V8, TIA Administrator and User Management Component (UMC). gDAP (gPROMS Digital Application Platform) is also listed for all versions, although the excerpt does not explicitly tie the CVE identifier to it.
Other products are affected only in specific ranges: SIMATIC BRAUMAT and SIMATIC SISTAR from 8.2.0.1 up to but not including 8.2.0.5, and SIMATIC WinCC OA V3.20 before 3.20.17.1. Versions beyond those boundaries are not listed as affected.
Siemens says it has released new versions for several products and advises customers to move to the latest releases. The vendor is working on further fixes and recommends specific mitigations where no fix exists yet; the advisory excerpt does not spell those mitigations out, so administrators should read the full Siemens bulletin.
The affected products are deployed worldwide, notably in critical manufacturing, food and agriculture, and energy. Teams running these environments should identify exposed installations without delay.
What to do now
- Inventory installations of WinCC, TIA Administrator, UMC, BRAUMAT, SISTAR, COMOS Walkinside and the other products named in the advisory.
- Update SIMATIC BRAUMAT and SIMATIC SISTAR to 8.2.0.5 or later, and SIMATIC WinCC OA V3.20 to 3.20.17.1 or later.
- For products without a fix, apply the mitigations described in the full Siemens advisory and watch for upcoming releases.
- As general good practice, restrict network access to these systems by keeping them behind firewalls and off the internet, and monitor for unusual activity.