Brotli 'Node2Shell' flaw affects Siemens Desigo CC and Gridscale X products
Siemens has confirmed that several of its software products are affected by CVE-2026-111497, an out-of-bounds write in the Brotli decoder dubbed 'Node2Shell'. Operators of Desigo CC and Gridscale X in manufacturing, energy and IT are advised to update.
What to do now
- Product
- Siemens Desigo CC, Gridscale X DSA, Gridscale X PSS®E (Brotli decoder)
- Affected versions
- Desigo CC V8 and V9: all versions; Gridscale X DSA >= 5.3 and < 5.4; Gridscale X PSS®E < 36.8.0; Brotli 1.0.3 through 1.2.0
- Fixed in
- Desigo CC: latest .NET security updates; Brotli 1.0.10, 1.1.1 or 1.2.1; latest Siemens releases
- CVE
- CVE-2026-111497
On 12 November 2026 CISA republished a Siemens advisory covering CVE-2026-111497, a vulnerability in the Brotli decoder known as 'Node2Shell'. The Node.js project, which bundles the decoder, shipped fixes on 21 October 2026.
The bug is a buffer overflow, specifically an out-of-bounds write, in c/dec/decode.c in Google Brotli versions 1.0.3 through 1.2.0 on every platform. A remote, unauthenticated attacker who supplies a crafted Brotli-compressed stream can corrupt the decoder's state memory. The same flaw can leak sensitive memory contents, crash the service or potentially lead to arbitrary code execution.
Siemens lists four affected products: every version of the Desigo CC family V8 and V9, Gridscale X DSA from 5.3 up to but not including 5.4, and Gridscale X PSS®E before 36.8.0. These products are deployed worldwide, notably in critical manufacturing, energy and information technology.
Siemens says new versions are available and recommends moving to the latest releases. For Desigo CC V8 and V9, the fix is to install the latest .NET security updates through Windows Update. For standalone Brotli libraries or binaries between 1.0.3 and 1.2.0, the fixed releases named are 1.0.10, 1.1.1 and 1.2.1.
The advisory does not say whether the vulnerability is being actively exploited.
What to do now
- On Desigo CC V8 and V9 workstations and servers, install the latest .NET security updates through Windows Update now.
- Update Gridscale X DSA 5.3.x and Gridscale X PSS®E builds older than 36.8.0 to the latest versions released by Siemens.
- Inventory other software for Brotli libraries or binaries from 1.0.3 to 1.2.0 and replace them with 1.0.10, 1.1.1 or 1.2.1.
- As general good practice, restrict network exposure of these industrial systems and watch for unexplained crashes of the affected services.