AutomationDirect C-More EA9: crafted project file can corrupt memory in programming software
CISA reports a heap-based buffer overflow in AutomationDirect's C-More EA9 Programming Software, triggered when a malicious project file is opened and potentially leading to code execution. Engineers and OT teams in manufacturing, energy and water using versions up to V6.80 are affected.
What to do now
- Product
- AutomationDirect C-More EA9 Programming Software
- Affected versions
- C-More EA9 Programming Software up to and including V6.80
- Fixed in
- V6.81
- CVE
- CVE-2026-127280
CISA has published an industrial control systems advisory for C-More EA9 Programming Software, AutomationDirect's tool for building projects for its C-More operator panels. The flaw, tracked as CVE-2026-127280, is a heap-based buffer overflow (CWE-122).
According to the advisory, the software does not properly validate data read from a project file before using it in heap memory operations. A crafted file overruns a heap buffer as soon as it is opened, corrupting application memory and causing instability or a crash. CISA says this could potentially lead to arbitrary code execution.
The attack requires user interaction: someone has to be persuaded to open the malicious file. The advisory names email, file sharing and removable media as likely delivery routes, all of which are routinely used to pass projects between integrators, engineering offices and plant sites.
All versions up to and including V6.80 are affected. AutomationDirect has released version 6.81, available from its software downloads page. The product is used worldwide, particularly in critical manufacturing, energy, and water and wastewater systems.
The issue was reported to CISA by rgod of TrendAI Zero Day Initiative. The advisory does not mention known exploitation. CISA also repeats its standard advice, including keeping control system devices off exposed networks.
What to do now
- Update C-More EA9 Programming Software to version 6.81 on every engineering workstation.
- Inventory machines still running V6.80 or earlier, including laptops used by integrators and contractors.
- Until patched, only open project files from verified sources and treat files arriving by email, file share or USB media with caution.
- As general good practice, minimise network exposure of engineering workstations and control system devices, as CISA recommends.